EDWARDS IPX 100 Products

  • EDWARDS: iPX 100

    Details
    ID#:
    54017
    Category:
    Pumps
    Pumps.
  • EDWARDS: iPX 100

    Details
    ID#:
    137641
    Category:
    Pumps
    Dry pumps, many available.
  • EDWARDS: iPX 100

    Details
    ID#:
    9068847
    Category:
    Pumps
    Pump.
  • EDWARDS: iPX 100

    Details
    ID#:
    9028253
    Category:
    Pumps
    Pump.
  • EDWARDS: Diffstak 100 / 300P

    Details
    ID#:
    137250
    Category:
    Pumps
    Diffusion pump | Pneumatically actuated high vacuum valve | Water-cooled | N2 pumping speed: 280L/sec | ISO 100 inlet | NW25 backing connection | Power requirements: 210-225VAC, 50/60Hz.
  • EDWARDS: EXT 100 / 300

    Details
    ID#:
    117748
    Category:
    Pumps
    turbo pump.
  • EDWARDS: iPX 180

    Details
    ID#:
    181615
    Category:
    Pumps
    Pump.
  • EDWARDS: iPX 100A

    Details
    ID#:
    9063152
    Category:
    Pumps
    Dry pumps.
  • EDWARDS: iPX 100A

    Details
    ID#:
    122609
    Category:
    Pumps
    Pump, 208V, 59 cfm.
  • EDWARDS: IGX3 / 100

    Details
    ID#:
    138524
    Category:
    Pumps
    Dry booster pump with roots pump packages | Voltage: 200-230 V.
  • BOC EDWARDS: Chemprep 100

    Details
    ID#:
    175033
    Category:
    Pumps
    Chemical blending module.
  • EDWARDS: iPX 180A

    Details
    ID#:
    9069256
    Category:
    Pumps
    Dry pumps.
  • EDWARDS: iPX 500A

    Details
    ID#:
    9020154
    Category:
    Pumps
    Dry pump, 400 V.
  • EDWARDS: iPX 500A

    Details
    ID#:
    9012919
    Category:
    Pumps
    Dry pumps with bellows.
  • EDWARDS: E306

    Details
    ID#:
    19187
    Category:
    Evaporators
    Box chamber | 4" Diffstak | Manual valve | 12" Bell jar chamber on modular base plate | E2M8 backing pump | Gauging | LT circuitry | EUR power input | The fixing kit has the seal and the clamps for the interface | System: | with diffusion pumping system, Edwards RV8, (8m3/hr) dual stage rotary pump, bell jar chamber. The vacuum chamber is mounted on top of the Edwards base plate and an implosion guard aids safety. Vacuum control will be via a manual high vacuum valve actuated from the front face of the evaporator frame. An active strain cold cathode type vacuum gauge will report chamber vacuum levels, whilst a pirani gauge will report backing / roughing vacuum levels. Interlocks will be provided for vacuum and cabinet doors. | Chamber: | The chamber will be based on the standard Edwards 360mm high glass bell jar which has to be lifted from the base plate to allow for access to the sample / techniques. A glass cylinder and top plate chamber is optional. An implosion guard is fitted over the bell jar. | Vacuum: | Ultimate vacuum specification of the system will be 1 x 10-6 mbar without the addition of liquid nitrogen to the cryo panel | Source shutter: | One manual source shutter, (operated from a mechanical lever on the left side of the base plate collar). Control is via the SQM160. | Process control: | Inficon SQM-160 thin film monitor complete with download software suite (Windows based). Also included here is one crystal head(s) with oscillator and cable set(s), RS232 cable and PC software. The SQM160 will interface to the source shutter. | TE4 thermal source: | Four discrete crucible / filament resistive evaporator with manual crucible selection via the Edwards control unit. The source is water cooled (option) and the electrical feed through kit provides power to the device. The source has cross contamination shielding, 400A rated feed through and 100A rated connection cables. Source PSU is the existing Edwards E306 unit. | Consumables: | Qty 5 Tungsten basket | Options: | Glow discharge | Thermal evaporation | E-beam deposition | Sample heating / cooling | Thin film monitor | Motorized shutters | 8-Sample rotation stage and cylinder chamber upgrade | Plasma Glo bar | ARDK-8 sample rotation stage and cylinder chamber upgrade | A glass cylinder and top plate chamber | Turbo molecular pump conversion | MiniBox front loading chamber upgrade | MiniBox shielding | MiniBox fixing kit | Step up transformer 120vac/60hz/1p input, 300VA rated.
  • EDWARDS: iH1800 HTX

    Details
    ID#:
    152261
    Category:
    Pumps
    Pump | Specifications: | Typical peak pumping speed: | m3/h: 1800 | cfm: 1060 | l/m: 30006 | Typical ultimate vacuum 60Hz (with shaft-seals purge only for iH): | mbar: 1.E-03 | Torr: 8.E-04 | Inlet Connection: ISO 160 bolted | Outlet Connection (iH pumps exhaust line must be metal for 2m): NW40 | Noise level (measured at I meter form the pump): dB(A): <69 | Nitrogen Supply Pressure: | Flow rates (with nitrogen supply capacity of 100 slm): psig: 20~100 | Nitrogen Flow (Low/ Light): slm: 4 | Nitrogen Flow (Med.): slm: 14 | Nitrogen Flow (Med+Exh): slm: 19 | Nitrogen Flow (High/ Harsh): slm: 44 | Nitrogen connector: 1/4" Swagelok | Cooling-water Connectors (Quick-release connectors (pair) thread size 3/8" BSP): Supplied | Water supply pressure: psig: <100 | Typical pressure differential across supply and return with flow of 7 l min-1: psig: 15 | Supply temperature: °C: 20 | Minimum flow rate required for reliable drypump system operation: l/min: 4 | Mains supply connector: Harting HAN-K-4/2 | Supply voltage: 200~230V, 380~460V 60 Hz | Phase: 60Hz, 3-phase | Motor rating: kW: 7.0 | Max Amps (FLA) Full Load Current (A) - Low voltage: A: 29.8 | Max Amps (FLA) Full Load Current (A) - High voltage: A: 14.4 | Power at ultimate vacuum: kW: 4.1 | Current at ultimate vacuum - Low voltage: A: 17.3 | Current at ultimate vacuum - High voltage: A: 10.4 | Fit a secondary earth: must fit | Crated.
  • EDWARDS: 4080+

    Details
    ID#:
    9020216
    Category:
    Chillers - Recircul...
    Chillers | | Performance (nominal): | Temperature range: -40°C to +80°C in 0.1°C increments | Cooling capacity: 700 W @ -40°C / 2400 W @ -20°C to +80°C | Heating capacity: 2250 W | Temperature stability: Coolant temperature control within 1.0°C of set point | Temperature ramp: +25°C to +80°C < 25 minutes | (no load): +25°C to -30°C < 15 minutes | Pump capacity: 3 gpm flow at 20°C at 60 psi, up to 100 psi system pressure | | Refrigeration system: | Refrigerant: HFC R404A | Compressor: 2.8 kW, 3 phase hermitically sealed | Heat exchanger: high efficiency cross flow plate | | Coolant circulation system: | Coolant fluid: perfluorocarbon coolant 3M FC-77, 3M FC-3283, 3M FC-8270, 3M HFE 7500, or Ausimont Galden HT110 | Pump: magnetic drive gear pump, 3/4 HP motor.
  • BOC EDWARDS: Auto 500

    Details
    ID#:
    9073803
    Category:
    Evaporators
    Thermal Resistance Evaporator Coater | Turbo Pump: Edwards EXT 255H / ISO 100K, P/N: B75301000S | Turbo Pump Controller: Edwards EXC 300 | Foreline Trap: Edwards FL20K | Vacuum Valve: Edwards PV25EKA | Rotary Vane Vacuum Pump: Edwards RV12 | Source Controls: (2) Dual Edwards Thyristor | Controller Modules: (2) Dual Edwards LT/HT with LT Transformer and HT Power Supply | Bell Jar: not included.
  • EDWARDS: IQDP40

    Details
    ID#:
    136415
    Category:
    Pumps
    Pump package with EDWARDS QMB 250.
  • EDWARDS: E306

    Details
    ID#:
    94348
    Category:
    Evaporators
    Vacuum evaporator with pumps and fixturing | Unit has bell jar with multiple feed throughs and rotation | Diffusion pumped with EDWARDS 2-stage backing pump | Unit was previously used for doing Cr/Au or Ni-Cr/Au | System's thermal source inputs were modified and hooked up with a heavy ARC welder power supply for lots of power | Jar is cracked.
Copyright © 2011 Capital Asset Exchange & Trading LLC. All rights reserved.